Omron NY532-5400 Troubleshooting Manual page 463

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Event name
Cannot Execute Save Cam Table Instruction
Meaning
You cannot save a cam table to a file when non-volatile memory is being accessed by another operation.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_COM.Obsr.Active
variables
Assumed cause
An attempt was made to execute
the MC_SaveCamTable instruc-
Cause and
tion when another operation was
correction
accessing the non-volatile mem-
ory (e.g., transfer or data trace
operation from the Sysmac Stu-
dio).
Attached
None
information
Precautions/
None
Remarks
NY-series Troubleshooting Manual (W564)
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Execute the MC_SaveCamTable
instruction again.
3 Error Descriptions and Corrections
Event code
743C0000 hex
MC Common
Detection
timing
---
Log category
Not affected.
Name
MC Common Observation Active
Prevention
None
At instruction
execution
System
3
3-387

Advertisement

Table of Contents
loading

Table of Contents