Appendix
Event code
Event name
77890000 hex
Homing
Opposite
Direction
Limit Input
Detected
778A0000 hex
Homing
Direction
Limit Input
Detected
778B0000 hex
Homing Limit
Inputs
Detected in
Both Direc-
tions
778C 0000 hex
Home Prox-
imity/Homing
Opposite
Direction
Limit Input
Detected
778D 0000 hex
Home Prox-
imity/Homing
Direction
Limit Input
Detected
A-10
Meaning
Assumed cause
The limit signal in
• The Operation Selection at
the direction oppo-
Negative Limit Input or Opera-
site to the homing
tion Selection at Positive Limit
direction was
Input parameter is set to No
detected during a
reverse turn.
homing operation.
• The location of the homing
input signal sensors, homing
settings, and homing start posi-
tion cause a limit input to be
reached.
• The input signal sensor wiring
is incorrect or the sensor is
faulty.
The limit signal in
• The Operation Selection at
the homing direc-
Negative Limit Input or Opera-
tion was detected
tion Selection at Positive Limit
during a homing
Input parameter is set to No
operation.
reverse turn.
• The location of the homing
input signal sensors, homing
settings, and homing start posi-
tion cause a limit input to be
reached.
• The input signal sensor wiring
is incorrect or the sensor is
faulty.
The limit signals in
• The wiring of the limit signal is
both directions
incorrect.
were detected
• The limit sensor is installed in
during a homing
the wrong location.
operation.
• The contact logic of the limit
signal is not correct.
• The limit sensor failed.
The home proxim-
• The wiring of the home proxim-
ity input and the
ity signal or limit signal is incor-
limit signal in the
rect.
direction opposite
• The home proximity sensor or
to the homing direc-
limit sensor is installed in the
tion were detected
wrong location.
at the same time
• The contact logic of the home
during a homing
proximity signal or limit signal is
operation.
not correct.
• The home proximity sensor or
limit sensor failed.
The home proxim-
• The wiring of the home proxim-
ity input and the
ity signal or limit signal is incor-
limit signal in the
rect.
homing direction
• The home proximity sensor or
were detected at
limit sensor is installed in the
the same time
wrong location.
during a homing
• The contact logic of the home
operation.
proximity signal or limit signal is
not correct.
• The home proximity sensor or
limit sensor failed.
Level
Maj
Prt
Min
Obs Info
S
O030
O030
S
S
O030
O030
S
S
O030
NY-series Troubleshooting Manual (W564)