Omron NY532-5400 Troubleshooting Manual page 113

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Event code
Event name
5401546A hex
Last Position Set-
ting Out of Range
5401546B hex
Illegal First/Last
Position Size Rela-
tionship (Linear
Mode)
5401546C hex
Master Sync Start
Position Setting
Out of Range
5401546D hex
Slave Sync Start
Position Setting
Out of Range
5401546E hex
Duplicate Latch ID
for Trigger Input
Condition
5401546F hex
Jerk Override Fac-
tor Out of Range
54015470 hex
Accelera-
tion/Deceleration
Override Factor
Out of Range
54015471 hex
First Position
Method Specifica-
tion Out of Range
54015472 hex
Motion Control
Instruction Re-exe-
cution Disabled
(First Position
Method)
NY-series Troubleshooting Manual (W564)
Meaning
The parameter specified for
• Instruction input
the LastPosition input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• The value of the Last-
the LastPosition input vari-
able to a motion control
instruction is smaller than
the parameter specified for
the FirstPosition input vari-
able.
The parameter specified for
• Instruction input
the MasterSyncPosition
input variable to a motion
control instruction is out of
range.
The parameter specified for
• Instruction input
the SlaveSyncPosition
input variable to a motion
control instruction is out of
range.
The same latch ID was
• The same latch ID is
specified for more than one
motion control instruction.
• The MC_AbortTrigger
The parameter specified for
• Instruction input
the JerkFactor input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the AccFactor input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the StartMode input vari-
able to a motion control
instruction is out of range.
An attempt was made to
• A parameter for an
change the StartMode input
variable when re-executing
a motion control instruction.
(This input variable cannot
be changed when re-exe-
cuting an instruction.)
3 Error Descriptions and Corrections
Assumed cause
Maj
Prt
parameter exceeded
the valid range of the
input variable.
Position input parame-
ter is less than the
value of the FirstPosi-
tion input variable for
the instruction when
the Count Mode is set
to Linear Mode.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
used simultaneously
for more than one of
the following instruc-
tions: MC_Touch-
Probe (Enable
External Latch)
instruction,
MC_MoveLink (Syn-
chronous Positioning)
instruction, and
MC_MoveFeed (Inter-
rupt Feeding) instruc-
tion.
(Disable External
Latch) instruction was
executed to cancel a
latch that was used by
an instruction other
than the MC_Touch-
Probe (Enable Exter-
nal Latch) instruction.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
input variable that
cannot be changed for
re-execution was
changed.
Level
Refer-
ence
Min
Obs
Info
S
page 3-243
S
page 3-244
S
page 3-245
S
page 3-246
S
page 3-247
S
page 3-248
S
page 3-248
S
page 3-249
S
page 3-250
3-37
3

Advertisement

Table of Contents
loading

Table of Contents