Motion Control Instruction Re-execution Disabled
Event name
(StartPosition)
An attempt was made to change the StartPosition input variable when re-executing a motion control
Meaning
instruction. (This input variable cannot be changed when re-executing an instruction.)
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].MFaultLvl.Active
variables
Assumed cause
A parameter for an input variable
that cannot be changed for re-
execution was changed.
Cause and
correction
Attached
None
information
Precautions/
None
Remarks
NY-series Troubleshooting Manual (W564)
Source details
Minor fault
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the program so that the
parameter for the relevant input
variable does not change when
the relevant instruction is re-exe-
cuted.
3 Error Descriptions and Corrections
54650000 hex
Event code
Axis
Detection
timing
Error reset
Log category
Operation is not possible for relevant axis. Relevant
axis decelerates to a stop if it is in motion.
Name
Axis Minor Fault Occurrence
Prevention
Check the manual to see if the
input variables to the relevant
motion control instruction can be
changed by re-execution. Write
the program so that the input
parameters for any input variable
that cannot be changed do not
change upon re-execution.
At instruction
re-execution
System
3
3-433

Advertisement