Omron NY532-5400 Troubleshooting Manual page 696

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Appendix
Event code
Event name
04A10000 hex
Non-volatile
Memory
Hardware
Error
 IO-Link Master Unit
Event code
Event name
04A10000 hex
Non-volatile
Memory Hard-
ware Error
04A20000 hex
Slave Hard-
ware Error
14A00000 hex
Non-volatile
Memory
Checksum
Error
847C0000 hex
Device Con-
figuration Veri-
fication Error
84840000 hex
I/O Cable
Short-circuit
84870000 hex
IO-Link Com-
munications
Module Pro-
cessing Error
84A00000 hex
Slave Unit
Verification
Error
84790000 hex
Error-level
Device Event
847A0000 hex
IO-Link Com-
munications
Error
84860000 hex
Warning-level
Device Event
Flag
84820000 hex
IO-Link
Device Con-
figuration
Information
Created
84850000 hex
I/O Power
Supply ON
Detected
A-50
Meaning
Assumed cause
An error occurred in
• Non-volatile memory failure
non-volatile mem-
ory.
Meaning
Assumed cause
An error occurred in
• Non-volatile memory
non-volatile mem-
failure
ory.
A hardware error
• The slave unit failed.
occurred in the
slave unit.
An error occurred in
• Noise
the control parame-
ters.
The connected
The connected device is
device is different
different from the IO-Link
from the IO-Link
device registered for a
device registered for
port of the IO-Link Master.
a port of the IO-Link
Master.
There is a short-cir-
There is a short-circuit in
cuit in the cable that
the I/O cable.
connects the IO-
An IO-Link device has
Link master and
failed.
device.
A hardware failure
A hardware failure
occurred in the IO-
occurred.
Link Communica-
tions Module.
An error occurred in
An error occurred in the
Slave Unit verifica-
control board.
tion.
An error-level event
Use CX-Configurator FDT
occurred in the IO-
to confirm the event code
Link device.
of the IO-Link device.
An error occurred in
• The I/O cable is broken.
IO-Link communica-
Or, the IO-Link device is
tions with a device.
disconnected from the
port.
• An IO-Link device has
failed.
• The communications
are affected by noise.
A warning-level
Use CX-Configurator FDT
event occurred in
to confirm the event code
the IO-Link device.
of the IO-Link device.
IO-Link device con-
IO-Link device configura-
figuration informa-
tion information was cre-
tion was created.
ated.
The I/O power sup-
The I/O power supply ON
ply ON was
was detected in several
detected in several
times.
times.
Level
Maj
Prt
Min
Obs Info
S
Level
Maj
Prt
Min
Obs
Info
S
S
S
S
S
S
S
S
S
S
S
S
NY-series Troubleshooting Manual (W564)
Reference
W488
Reference
W570
W570
W570
W570
W570
W570
W570
W570
W570
W570
W570
W570