Omron NY532-5400 Troubleshooting Manual page 531

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Event name
Cam Transition Specification Out of Range
The parameter specified for the CamTransition input variable to a motion control instruction is out of
Meaning
range.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].MFaultLvl.Active
variables
Assumed cause
Instruction input parameter
Cause and
exceeded the valid range of the
correction
input variable.
Attached
None
information
Precautions/
None
Remarks
Synchronized Control End Mode Selection Out of
Event name
Range
Meaning
The parameter specified for the OutMode input variable to a motion control instruction is out of range.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].MFaultLvl.Active
variables
Assumed cause
Instruction input parameter
Cause and
exceeded the valid range of the
correction
input variable.
Attached
None
information
Precautions/
None
Remarks
NY-series Troubleshooting Manual (W564)
Source details
Minor fault
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the parameter so that the
valid range of the input variable is
not exceeded for the relevant
instruction.
Source details
Minor fault
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the parameter so that the
valid range of the input variable is
not exceeded for the relevant
instruction.
3 Error Descriptions and Corrections
Event code
54900000 hex
Axis
Detection
timing
Error reset
Log category
Operation is not possible for relevant slave axis.
Relevant slave axis decelerates to a stop if it is in
motion.
Name
Axis Minor Fault Occurrence
Prevention
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
54910000 hex
Event code
Axis
Detection
timing
Error reset
Log category
Operation is not possible for relevant slave axis.
Relevant slave axis decelerates to a stop if it is in
motion.
Name
Axis Minor Fault Occurrence
Prevention
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
At instruction
execution
System
3
At instruction
execution
System
3-455

Advertisement

Table of Contents
loading