CLI Commands: Base

4.4.20 serial timeout

This command specifies the maximum connect time (in minutes) without
console activity. A value of 0 indicates that a console can be connected in-
definitely. The time range is 0 to 160.
Default
5
Format
serial timeout <0-160>
Mode
Line Config
no serial timeout
U
This command sets the maximum connect time without console activity
(in minutes) back to the default value.
Format
no serial timeout
Mode
Line Config

4.4.21 set prompt

This command changes the name of the prompt. The length of name may be
up to 64 alphanumeric characters.
Format
set prompt <prompt string>
Mode
Privileged EXEC
92
4.4 Management Commands
Release 8.0 05/2013
CLI L2E