4.9.18 lldp config chassis tx-hold-mult

Configure the LLDP transmit hold multiplier, a time-to-live value expressed
as a multiple of the LLDP Message Tx Interval (tx-interval), min.: 2, max.: 10,
default: 4.
Format
lldp config chassis tx-hold-mult
Mode
Global Config
Tx-hold-mult
Configure the LLDP transmit hold multiplier, a time-to-live value
expressed as a multiple of the LLDP Message Tx Interval (tx-interval),
min.: 2, max.: 10, default: 4.

4.9.19 lldp chassis tx-interval

Configure the interval at which LLDP frames are transmitted on behalf of this
LLDP agent (unit: seconds, min.: 5 sec., max.: 32768 sec., default: 30 sec.)
Format
lldp chassis tx-interval <tx interval>
Mode
Global Config
Tx-interval
Configure the interval at which LLDP frames are transmitted on behalf
of this LLDP agent (unit: seconds, min.: 5 sec., max.: 32768 sec.,
default: 30 sec.).