4.8.24 signal-contact connection-error

This command configures the signal contact link error monitoring for this port.
Format
signal-contact connection-error {disable|enable}
Mode
Interface Config
disable
A link down event on this port will be not monitored by a signal con-
tact (default).
enable
A link down event on this port will be monitored by a signal contact.

4.8.25 signal-contact

This command configures the signal contacts.
Format
signal-contact {1|2|all}
{mode {auto|device-status|manual}
|monitor {aca-removal|
all|
connection-error|hiper-ring|module-removal
|power-supply-1| power-supply-2
|power-supply-3-1|power-supply-3-2
|power-supply-4-1|power-supply-4-2
|ring-coupling|temperature} {disable|enable}
|state {closed|open}
|trap {disable|enable} }
Mode
Global Config
CLI L2E
Release 8.0 05/2013