Element 55 (550 ms) is the ±1.0 millisecond error flag. Element 55 is set to Binary
1 when the expected time error is within +/- 1.0 millisecond, and a Binary 0 dur
ing all other conditions of operation.
Element 56 (560 ms) is the ±5.0 millisecond error flag. Element 56 is set to Binary
1 when the expected time error is within +/- 5.0 milliseconds. and a Binary 0 dur
ing all other conditions of operation.
Element 57 (570 ms) is the ±50 millisecond error flag. Element 57 is set to Binary
1 when the expected time error is within +/- 50 milliseconds, and a Binary 0 dur
ing all other conditions of operation.
Element 58 (580 ms) is the ±500 millisecond error flag. Element 58 is set to Bin
ary 1 when the expected time error is within ±500 milliseconds, and a Binary 0
during all other conditions of operation.
Table 5-30:
FAA Time Error Indicators
Time Since Loss of Lock
N/A
< 00:16:40
00:16:41 to 01:23:39
01:23:40 to 13:53:19
13:53:20 to 5 days
18:53:19
>5 days 18:53:20
N/A
SecureSync User Reference Guide
Lock Indic
Status/Error
Locked Error < 2μs
1
Unlocked Error < 1ms
0
Unlocked Error < 5ms
0
Unlocked Error < 50 ms 0
Unlocked Error < 500
0
ms
Unlocked Error
0
Unknown
Power On
0
±1ms ±5ms ±50 ms ±500 ms
ator
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
0
0
0
0
0
0
APPENDIX
0
0
0
0
1
0
0
533