performed. With the Timescale field set to "Local", select the name of a previously
created Local Clock. The Time Zone and DST rules, as configured in the Local
Clock will be applied to the front panel time display. Refer to for more inform
ation on Local Clocks.
Reference Selection : Selects TOD 1 or TOD 2 (configured below) which TOD signal is
used for synchronization.
Time of Day Settings tab
For Time of Day 1 and Time of Day 2 (STANAG content supports two ToD streams).
ToD Format : The user-selectable format to be used. Available formats include:
STANAG 4246 HAVE QUICK I
STANAG 4246 HAVE QUICK II
STANAG 4372 HAVE QUICK IIA
STANAG 4430 Extended HAVE QUICK
SecureSync User Reference Guide
APPENDIX