Configuring "Ntp Stratum Synchronization - Spectracom SecureSync 1200 User Reference Manual

Time & frequency reference system
Table of Contents

Advertisement

2.15  Configuring NTP
use the System Time as a reference to NTP, since this provides NTP with the most accurate ref
erences. This mode is called Stratum 1 operation, since SecureSync operates as a Stratum 1
NTP server.
To configure Stratum 1 operation for SecureSync:
1.
Navigate to MANAGEMENT > NETWORK: NTP Setup :
2.
Click the GEAR icon in the NTP Services panel.
3.
The Edit NTP Services window will display. Click the Stratum 1 tab.
4.
Check
5.
Click the Submit button.

2.15.7.3 Configuring "NTP Stratum Synchronization"

NTP Stratum Synchronization refers to the concept of using a different NTP Server or Peer as
your primary reference (instead of e.g., GNSS). This will make the SecureSync you are con
figuring a Stratum 2 server, since the other server is Stratum 1.
To configure Stratum 2 (or greater) operation for SecureSync:
1.
Navigate to MANAGEMENT > NETWORK: NTP Setup :
2.
Click the GEAR icon in the NTP Services panel.
3.
The Edit NTP Services window will display. Click the Stratum 1 tab.
98
all of the three options
:
Enable Stratum 1 Operation
Checking this option will cause the NTP Service to use the System Time provided
by the Timing System input.
Prefer Stratum 1
This option configures NTP to "weigh" the Timing System input heavier than input
from other NTP servers for its selection (The Timing System inputs are normally
more accurate than other NTP servers).
However, if the Timing System inputs are not normally available (such as with
intermittent GNSS reception or no other inputs are available), it may be desir
aable NOT to prefer the Timing System over an NTP reference, in which case this
box should not be checked.
Enable Stratum 1 1PPS
This option determines whether or not NTP uses the 1PPS input from the Timing
System. The 1PPS input to NTP needs to correlate with its "Time" input. If the Time
and PPS inputs are originating from the same source, they will be correlated.
However, if the time is originating from another NTP server, but the 1PPS is being
derived by the Timing System, the two inputs may not always correlate. Without
this correlation, NTP performance will be degraded. In such a scenario, it is best
NOT to use the System Time's 1PPS as a reference.
CHAPTER
2
SecureSync User Reference Guide Rev. 23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SecureSync 1200 and is the answer not in the manual?

Questions and answers

Cindy Dykstra
March 24, 2025

How to list all the client hosts on SecureSync 1200?

Related Products for Spectracom SecureSync 1200

Table of Contents

Save PDF