For U.S. only: AC outlet

The AC connection must fulfill the requirements specified in Table 4-20.
Table 4-20
Electrical Connection Values (for U.S. only)
Nominal
Nominal voltage range
voltage
from
120 V AC/
110 V AC
60 Hz
AC Power Outlet Requirements
The power source may not be more than 2 m (6 ft.) from the system.
The power source must supply a voltage of 120 V AC (single phase, fused) in 50-60 Hz.
A warning should be attached to the circuit breaker to prevent accidental removal of power.
An independent electric circuit with an isolated ground conductor should be used.
Recommendation: Add a power surge protector between the outlet and the system.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Nominal Frequency
to
from
130 V AC
47 Hz
Wall Outlet Configura-
Range
to
63 Hz
NEMA 5-15, 2-pin, 3-
wire, earth