Configuring Hipath 5000 With Hipath Comscendo Service - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

start_h5.fm
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
6.10.1

Configuring HiPath 5000 with HiPath ComScendo Service

The customer database must be loaded to enable the individual IP workpoint clients, trunks,
etc. to be configured.
Procedure
1.
StartHiPath 3000 Manager E.
2.
Open the Transfer dialog using the File menu.
3.
In the Communication Settings tab select IP-HiPath as the access and enter the IP ad-
dress of the HiPath 5000 with HiPath ComScendo Service in the appropriate field.
Select Read/Write CDB and load the customer database by clicking the System -> PC
button.
During the first login, the system requests the identity of the user and asks for a
>
new password (for more information see Section 12.6.1.1, "Logon With User
Name and Password").
4.
Perform the customer-specific system programming.
Refer to the HiPath 3000 Manager E Help for information on programming individual fea-
tures.
5.
Save the customer database.
6.
Then switch to the Transfer dialog.
7.
In the Communication Settings tab select IP-HiPath as the access and enter the IP ad-
dress of the HiPath 5000 with HiPath ComScendo Service in the appropriate field.
Select Read/Write Database. Set the Overwrite and Hardware flags and transfer the cus-
tomer database by clicking the PC –> System button.
Once transfer is complete, HiPath 5000 automatically performs a reset and then returns to
operation.
The HG 1500 resources (see Page 10-38) are to be administered with Web-based
>
Management (WBM). Information about the procedure can be found in the Web-
based Management WBM Help.
6-48
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual