Optipoint Recorder Adapter - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

wclient.fm
Workpoint Clients
optiPoint 500
10.2.3.5

optiPoint Recorder Adapter

The optiPoint recorder adapter allows an external recorder or a second headset to be connect-
ed. The called party must be informed that the call is being recorded.
1
Figure 10-17
optiPoint Recorder Adapter
10-28
Assignment of both connection jacks:
1
MW4 port for second headset
2
2
MW6 port for recorder
Contacts 2+3 and 4+5 are bridged
internally.
Recorders to be connected must meet the following electrical re-
quirements:
Input impedance: >10 kΩ
Frequency progression: 300 to 3000 Hz ± 3 dB
Beep tone level: -26 dBm to -18 dBm at a 600 Ω load
Max. input level: 650 mVeff from a 600 Ω source
Pin
Signal
1
Tx–
2
Rx
3
Rx
4
Tx+
Pin
Signal
1
Free
2
NF
3
NF
4
NF
5
NF
6
Free
P31003-H3550-S403-4-7620, 02/05