4.2.7.3.1
Installing the S
Installation Procedure
Caution
7
The patch panel must be installed above the system cabinet.
A minimum of one height unit must be kept clear above the cabinet to guarantee suf-
ficient ventilation of the system cabinet. This is achieved by the gray plastic cover
fixed to the top of the system cabinets. Never remove this plastic cover.
Insert the S
patch panel (A, in Figure 4-44) above a system cabinet and secure it to the 19-
0
inch frame on both the left and the right using two screws (B) on each side.
Figure 4-44
Installing the External S
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Patch Panel in the 19-Inch Cabinet
0
A
B
0
Patch Panel in the 19-Inch Cabinet
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4-75