Installing Hipath 3500 And Hipath 3300 (19-Inch Housing); Installation Versions - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.4.4

Installing HiPath 3500 and HiPath 3300 (19-Inch Housing)

This section contains information on how to install the HiPath 3500 and HiPath 3300 19-inch
housing. This chapter describes the standard installation procedures for the basic system. Re-
fer to Chapter 9 for information about supplementary equipment and expansions.
Danger
7
The HiPath 3500 and HiPath 3300 systems can only be operated with a closed hous-
ing.
Before opening the housing, make sure that the system is de-energized as follows:
Disconnect the line cord on any connected battery pack (for UPSC-DR only).
Disconnect the line cord on any connected EPSU2-R (for UPSC-DR only).
Disconnect the power plug.
4.4.4.1

Installation Versions

HiPath 3500 and HiPath 3300 are designed for the following three installation variants:
Wall mounting (with assembly kit 39165-A7027-D2)
Desk installation (assembly kit includes adhesive feet 39165-A7027-D2.)
Stick the adhesive feet to the bottom of the housing.
Installation in the 19-inch cabinet (with assembly kit 39165-A7027-D1 for HiPath 3500, as-
sembly kit 39165-A7027-D4 for HiPath 3300)
You can also install an ECR expansion cabinet rack in which you can install a battery pack (for
uninterruptible power supply) and/or an additional external power supply EPSU2-R (if the sys-
tem's internal power supply is not sufficient) (see Section 9.2.4).
4-186
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 5000