Table 12-7
HiPath 3000 Class B Error Messages
No.
Error Class B-01 - HiPath 3000 Manager E
3
Hard restart
10
Hard restart using SNMP
14
"On site" changes to the database
15
"Remote" changes to the database (re-
mote service)
16
APS transfer acknowledgement message
17
No authorization to access IP address on
HiPath 3000
(IP add. in data[1...4])
18
Overflow in the MMC log area (log file)
19
Sensor alarm: Fan failure (19" housing for
HiPath 3500/HiPath 3300)
20
Overflow in the CDR buffer (CDR informa-
tion)
21
Error when identifying (name) and au-
thenticating (password):
from HiPath 3000 Manager E –>
Data[0] = 0, Data[1..9] = call number
number ->
Data[0] = 1, Data[1..4] = IP address
22
Flash area deleted
23
SNMP process stopped
24
No access authorization for IP application
(IP add. in data[1...4])
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Meaning
Action
Recovery
Hard restart
Hard restart
Unauthorized access at-
If necessary, configure
SNMP community/appli-
Check to see if the fan has
broken down and/or if the
ventilation openings in the
housing are unblocked.
Check interfaces (V.24,
Unauthorized access at-
If necessary, configure
SNMP community.
APS transfer possible
Perform hard restart
Unauthorized access at-
If necessary, configure ap-
plication firewall (IP ad-
dress/application flag).
service.fm
Service
Guided Maintenance
Action
Technician
tempt.
cation firewall.
Read out log file
LAN)
tempt.
again
tempt.