Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Options
3.4.6

EVM

Introduction
The optional subboard EVM (Entry Voice Mail) provides the functionality of integrated Voice
Mail in HiPath 3550, HiPath 3350,HiPath 3500 and HiPath 3300. The central control boards
S30810-Q2935-A301 (CBCC) and S30810-Q2935-Z301 (CBRC) must be used for this.
The board is plugged directly into the X32 connector on the central control boards CBCC (see
Figure 3-1) or CBRC (see Figure 3-2) using the connector strip X2.
Caution
7
The EVM subboard must not be plugged in or out when the system is energized.
Place the central control board on a flat surface before inserting the EVM subboard.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-144).
Otherwise you may damage the board.
HiPath Entry Voice Mail has capacity to store up to two hours of recorded messages. You can
create up to
24 standard mailboxes and
four Auto Attendant mailboxes.
Information on administering HiPath Entry Voice Mail for HiPath 3000 can be found in the Hi-
Path 3000 Manager E Help.
Caution
7
If using a different voicemail application (such as HiPath Xpressions Compact), the
EVM voice mail ports must be deactivated. To do this, set the ports to the "Standard"
station type and remove them from the active voicemail hunt group. Next set the
number of mailboxes for autoconfiguration to "0". This prevents the user making ac-
cidental changes to Call Management.
3-332
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual