Setting Up A Two-Cabinet System Side By Side - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

4.2.3.3.4

Setting Up a Two-Cabinet System Side by Side

Caution
7
To guarantee sufficient ventilation in the system cabinets, allow a minimum clear-
ance of 50 mm between the base of the cabinets and the ground.
Procedure
Step
1.
Place the system cabinet in the installation site and make sure that it is level and
stable.
2.
Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
3.
If necessary, set up the basic cabinet in the following way:
Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
4.
Place the expansion cabinet beside the basic cabinet.
Note: The cabinets can be placed directly beside one another.
5.
Check that the space between the base of the expansion cabinet and the ground
is at least 50 mm.
6.
If necessary, set up the expansion cabinet as described in Step 3 ensuring that
both cabinets are at exactly the same level.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Activity
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 5000

Table of Contents