V.24interface
The
V.24 cable
(C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
Transmission rate
Data bits
Parity bit
Stop bits
Data flow control
It is recommended that the local echo be deactivated on the connected terminal or PC.
Table 3-101
STMI2 - V.24 Interface Assignment
Pin
Signal
1
DCD
2
RxD
3
TxD
4
DTR
5
0 V
6
DSR
7
RTS
8
CTS
9
RI
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
38,400 (default)
8
None
1
None
I/O
Not used
I
Internal pull-up resistor in level switch (MAX211E)
O
O
Ground
I
Internal pull-up resistor in level switch (MAX211E)
O
I
Internal pull-up resistor in level switch (MAX211E)
Not used
Boards for HiPath 3000
Peripheral Boards
Remark
boards.fm
3-225