boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.9

PBXXX

Introduction
The PBXXX (Peripheral Board XXX) module can be used in HiPath 3800 to support country-
specific CAS protocols.
The board converts the Euro-ISDN protocol on an S
naling (CAS) protocol. The board functions only in conjunction with a DIUN2. PBXXX must al-
ways be plugged in to the left, next to DIUN2.
Because the PBXXX card is not recognized by the hardware, offline configuration is required
with HiPath 3000 Manager E. DIUN2 + PBXXX should be specified as the module to be con-
figured. After configuration, the module data can be seen in HiPath 3000 Manager E. However,
this is only visible in the software configuration, as the PBXXX card was only configured on the
software side.
Note: The offline configuration of the PBXXX serves solely to visualize the card with HiPath
3000 Manager E.
Front panel
Seven-segment display
Figure 3-60
PBXXX (S30810-Q6401-X) Front Panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
>
tion on mounting the shielding panel, see Section 4.2.5.2.
3-130
link into the Channel Associated Sig-
2M
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual