Connecting Cables and the Line Network

Not for U.S. and Canada Connection cable for the expansion cabinet rack ECR (if
present)
To meet EMC requirements, the braided shields on the connection cable must be connected to
the housing on the HiPath 3500 or HiPath 3300 side and on the ECR side.
Attaching to the HiPath 3500 or HiPath 3300 side
A clip and a tooth lock washer are enclosed with the ECR mounting set. Use these and the
housing cover mounting screw to attach the braided shield to the HiPath 3500 or HiPath
3300 housing (as shown in Figure 4-110). The tooth lock washer must be mounted be-
tween the painted surface of the cover and the clip.
Figure 4-110
Attaching to the ECR side (see Page 9-9)
Line network
The connecting cords to the peripherals can be connected directly to the relevant MW8 jacks
on the front panel of the 19-inch housing.
4-194
HiPath 3500 and HiPath 3300 - Connection Cable to ECR
Housing cover mounting screw
Clip
Tooth lock washer
Housing cover