Siemens HiPath 3000 Service Manual page 189

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

LED statuses and their meanings
Table 3-50
IVMP8 and IVMP8R (not for U.S.) - LED Statuses
LED
LED
Yellow
Green
During Startup and Initialization
Off
Off
On
On
On
Off
Off
Flashing
Off
(500/
500 ms)
Off
On
On
Off
During Operation
Off
On
Off
Flashing
(500/
500 ms)
Flashing
Flashing
(500/
(500/
500 ms)
500 ms)
On
Off
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Meaning
1 Boot procedure (lasts approx. 8 -
12 s)
2 LED test (lasts approx. 10 s)
3 Lockout switch state signaling by
yellow LED (lasts approx. 5 s):
blocked = On
free = Off
4 Hard disk test, start of the applica-
tion (depending on hard disk status,
lasts approx. 3 - 8 minutes)
5a Standby mode after successful boot
5b Board locked or board error oc-
curred
Idle (no call)
At least one active port (call)
Lockout switch activated during a call
Board locked or board error occurred
Boards for HiPath 3000
Peripheral Boards
Action
Possibly check if board was de-
activated using HiPath 3000
Manager E or lockout switch.
Check whether board was de-
activated using HiPath 3000
Manager E or lockout switch.
Check whether board was de-
activated using HiPath 3000
Manager E or lockout switch.
boards.fm
3-123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 5000

Table of Contents