Table 4-17 Hipath 3750 And Hipath 3700 - Static Traffic Capacity - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

Static traffic capacity
The static traffic capacity of the HiPath 3750 and HiPath 3700 systems can be determined as
follows.
Table 4-17
HiPath 3750 and HiPath 3700 - Static Traffic Capacity
HiPath 3750
HiPath 3700
Single-cabinet sys-
tem
(see Figure 4-89)
Two-cabinet system
(see Figure 4-90)
Three-cabinet sys-
tem
(see Figure 4-91)
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Slots per PCM seg-
ment
02 + 03
04 + 05
06 + 07 + 08
02 + 03
04 + 05
06 + 07 + 08
10 + 11
12 + 13
14 + 15
16 + 17
02 + 03
04 + 05
06 + 07 + 08
10 + 11 + 19 + 20
12 + 13 + 21 + 22
14 + 15 + 23 + 24
16 + 17 + 25 + 26
Installing HiPath 3750, HiPath 3700
Static traffic capac-
ity per PCM seg-
ment
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
64 erlangs
inst_h3.fm
Installing HiPath 3000
Total static traffic
capacity of the
system
192 erlangs
448 erlangs
448 erlangs
4-159