Siemens HiPath 3000 Service Manual page 158

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral Boards
LED statuses and their meanings
Table 3-32
DIUN2 - LED Statuses
Red LED
Green
LED
Off
Off
On
Off
Flashing
Off
Off
On
Off
Flashing At least one channel is activated.
Connection types
Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
AMOM
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
Copper cable
The copper cable is only connected via the 15-pin Sub-D jacks on the front panel.
3-92
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Loadware loading not successfully com-
pleted. Board is faulty.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000 Manager E.
Loadware is being loaded.
Board test completed successfully. Board is
OK (idle state).
Check plug contact on
board.
Replace board.
Replace board.
Check whether the board
was deactivated using Hi-
Path 3000 Manager E. If
not, replace board.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Action