Figure 3-130 S 2M Trunk Connection - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral Boards
S
trunk connection
2M
HiPath 3550, HiPath 3500
TS2/TS2R
Figure 3-130
S
2M
Keep the cable from the NT to HiPath 3550 or HiPath 3500 as short as possible to ensure prop-
er operation.
Caution
7
There should be absolutely no ground connection between the HiPath 3550 wall
housing and the NT. Do not connect the shield of the connection cable you are using
either on the HiPath 3550 side or on the NT side.
If the HiPath 3550 system is separately grounded (such as with the 19-inch housing
of the HiPath 3500), you may make a connection between HiPath 3550 and NT.
NT1 power supply
TS2 board
The NT1 supply voltage of –48 V can be tapped from the X2 connector (see Table 3-148).
There is a power limit of < 15 W for this voltage, which the system feeds over the CUC.
TS2R board
The NT1 power supply must come from an S30122-X7321-X (S30122-X7321-X100 with
UPS operation) power supply unit.
3-310
Trunk Connection
Public network
NT1
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual