Table 5-10 Run Led - Led Status Meaning; Supplying The System With Power - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
5.4.2

Supplying the System With Power

Procedure
Step
1.
Plug in the power supply cable and, where applicable, the battery cable.
2.
Monitor the Run LED of the central controller. The individual steps of the system
boot (Table 5-10) can be observed this way.
HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 RUN LED
The central board has a RUN LED that indicates the system status.
Table 5-10
RUN LED - LED Status Meaning
RUN LED
Off
on
Off
On
Off
for 0.1 s
Flashing
0.5 s on/0.5 s off
Flashing
0.1 s on/0.1 s off
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
The system is ready when the date "1. JAN 00" and the time "00:00" appear in the
>
display on the system telephone.
5-20
No power
Reset switch pressed briefly
Reset switch held down for more than 5 seconds (LED is extinguished
to acknowledge that a reload has begun)
System boot
Load operation: APS in SDRAM, loadware, and card data.
Normal operating state (zero load)
MMC removed or defective