LED statuses and their meanings
H1 (red) and H2 (green) LEDs
Table 3-146
Red LED
Green
LED
Off
On
Flashing
Off
Off
Flashing At least one subscriber line circuit is acti-
H3 LED (see Figure 3-121): Reference clock display (clock is generated if this feature was
configured using HiPath 3000 Manager E).
On: Reference clock for clock generator is created.
Off: No reference clock
3-300
TMS2 (Not for U.S.) - LED Statuses
Off
Board not receiving power or not
plugged in correctly.
Board is out of order.
Off
Board is receiving power and board test
is in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Loadware loading not successfully com-
pleted. Board is faulty.
Error detected on board.
Board is deactivated (not applicable to
errors detected by test loops) or board
was deactivated using HiPath 3000 Man-
ager E.
Off
Loadware is being loaded.
On
Board test completed successfully.
Board is OK (idle state).
vated.
Status
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Action
Check plug contact on
board.
Replace board.
Replace board.
Check whether the
board was deactivated
using HiPath 3000 Man-
ager E. If not, replace
board.
P31003-H3550-S403-4-7620, 02/05