Starting Up HiPath 3000
Starting Up HiPath 3800
5.2.3

Carrying Out a System Reload

After supplying the system with power, you must carry out a system reload.
Procedure
The reset/reload switch is tested by a Field Programmable Gate Array (FPGA). This
>
FPGA is loaded by the processor when starting up the HiPath 3800 and is only fully
functional after the loading process is complete. If the reset/reload switch is activated
during loading, then it is not possible to evaluate the cause of the restart. For this
reason, the reset/reload switch may only be activated after the system startup (green
Run LED lights up).
Press and hold down the reset switch for at least 5 seconds (FAIL LED (red) goes out). If you
do not hold down the reset switch for a full 5 seconds, the system may perform a reset rather
than a reload or may not reload properly.
5-6
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual