5.3.2.1

Assigning Station Numbers

The first time the system is initialized, the system determines its capacity and stores the result
in the CDB (customer database). After each system reset, the system accesses this data and
generates a continuous numbering plan.
If the system detects changes to the board configuration during startup, the following action is
taken:
If
Missing or defective board
Different board type
Underequipped or same
board variant
Over-equipped board variant Board is activated. The old station range is activated and the
New board in empty slot
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
No action.
The system does not automatically activate the board.
Board is activated. The same station range is used.
ports associated with the new board are inserted at the end.
The ports are split if there is no contiguous station range avail-
able.
Board was the last one installed in accordance with the
placement sequence:
All boards are activated and the numbering plan continues
without a gap.
Board was inserted ahead of another board in the place-
ment sequence:
Board is activated and appended to the last board in the
numbering plan.