12.6.1.4

Customer Data Security

When saving a customer database on the hard disk, a user table (part of the user administra-
tion) with user name and encrypted passwords are also saved. This guarantees access secu-
rity when the customer database is opened offline later on.
When opening the customer database offline, you are requested to enter your user name and
password. The data that you enter is compared to the data in the user table. In this case, the
user group verified during this process also determines the access rights.
When loading an offline customer database into HiPath 3000, the user table that goes with it
should not be loaded into the system. Otherwise, the system-specific user administration would
be distorted.
When you generate a default customer database offline, a default user table is also
>
set up. If you generate a customer database like this, you can only load it into a de-
fault system.