Installation notes
The EPSU2 AC/DC converter is designed for installation indoors only.
The unit is suitable only for mounting on the wall (vertically, with AC port on bottom).
Always install the units in a dry, dust-free area where there is no danger of vibrations.
Always make sure there is sufficient air circulation around the units. Do not block the ven-
tilation holes.
When selecting the location, keep in mind the necessary lengths of the following cables:
– AC cable (grounding plug, IEC 320 socket)
– DC cable to UPSC-D, length = 2 m
Procedure: EPSU2 wall-mounting
Step
1.
Drill two holes for anchors (5 mm in diameter) in the wall, as shown in Figure 3-68.
Depending on the wall materials, you may have to use a different kind of attach-
ment, such as wood screws for timber walls.
2.
Insert the anchors and insert two screws (3.5 mm in diameter), leaving 5 mm pro-
jecting from the wall.
3.
Mount the EPSU2 onto the screws and tighten them all the way.
Figure 3-68
EPSU2 - Holes for Mounting on the Wall
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
115 mm
102 mm
Activity
33 mm
317 mm
boards.fm
Boards for HiPath 3000
Peripheral Boards
3-155