STRB contact assignment
Table 3-166
STRB Contact Assignments
Connector
Contact
X3
X4
X5
X6
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Signal Name
1
K 4.21
2
K 4.22
3
K 4.23
4
K 3.21
5
K 3.22
6
K 3.23
7
K 2.21
8
K 2.22
1
K 2.23
2
K 1.21
3
K 1.22
4
K 1.23
5
+12VI
6
OPTKP 2
7
+12VI
8
OPTKP 1
1
K 3.12
2
K 3.13
3
K 2.11
4
K 2.12
5
K 2.13
6
K 1.11
7
K 1.12
8
K 1.13
1
OPTKP 3
2
+12VI
3
OPTKP 4
4
+12VI
5
K 4.11
6
K 4.12
7
K 4.13
8
K 3.11
Function
Relay contact K4.2 (common)
Relay contact K4.2 (NO)
Relay contact K4.2 (NC)
Relay contact K3.2 (common)
Relay contact K3.2 (NO)
Relay contact K3.2 (NC)
Relay contact K2.2 (common)
Relay contact K2.2 (NO)
Relay contact K2.2 (NC)
Relay contact K1.2 (common)
Relay contact K1.2 (NO)
Relay contact K1.2 (NC)
+12-V control voltage optocoupler
Control input optocoupler 2
+12-V control voltage optocoupler
Control input optocoupler 1
Relay contact K3.1 (NO)
Relay contact K3.1 (NC)
Relay contact K2.1 (common)
Relay contact K2.1 (NO)
Relay contact K2.1 (NC)
Relay contact K1.1 (common)
Relay contact K1.1 (NO)
Relay contact K1.1 (NC)
Control input optocoupler 3
+12-V control voltage optocoupler
Control input optocoupler 4
+12-V control voltage optocoupler
Relay contact K4.1 (common)
Relay contact K4.1 (NO)
Relay contact K4.1 (NC)
Relay contact K3.1 (common)
boards.fm
Boards for HiPath 3000
Options
3-359