boards.fm
Boards for HiPath 3000
Peripheral Boards
LAN interfaces
Table 3-43
HXGS3/HXGR3 - LAN Interface Assignment
Pin on
HXGS3/HXGR3
(X2 and X3)
1
3
4
6
Signals TT1/2 and RT1/2 are not needed for transmitting data. They represent a signal termi-
nation of 100 ohms (so-called Bob Smith termination) for the two unused wire pairs in a 4-pair
twisted pair cable.
3-104
Pin of RJ45 con-
nector
1
TDP (Transmit Data +)
2
TDN (Transmit Data –)
3
RDP (Receive Data +)
4
TT1 (Transmit Termination 1)
5
TT2 (Transmit Termination 2)
6
RDN (Receive Data –)
7
RT1 (Receive Termination 1)
8
RT2 (Receive Termination 2)
Signal