H300 LED (see Figure 3-85): Reference clock display (clock is generated if this feature was
configured using HiPath 3000 Manager E).
On: Reference clock for clock generator is created.
Off: No reference clock
LEDs H301 to H308 (see Figure 3-85)
Table 3-96
STMD8 - LED Statuses (H301 to H308)
LED Status
(on/off)
During Startup and Initialization
Flickering
(50/50 ms)
Flashing
(100/100 ms)
On
Flashing
(100/100 ms)
Off
Flashing
(500/500 ms)
During Operation
On
Flickering
(450/50 ms)
Flashing
(500/500 ms)
Off
3-212
Meaning
Board test unsuccessful
Board not configured
Loading in progress
Code could not be loaded
Board loaded
Board loaded but not yet activated
ISDN layer 2 activated
Dependability test (loopback test)
in progress
Board is out of service (e.g. S300/x
"closed")
ISDN layer 2 not activated
Replace board.
Inspect visually, remove and re-insert
board if necessary.
Replace board if flashing continues.
Replace board.
Check whether board was deactivat-
ed using HiPath 3000 Manager E or
lockout switch.