Loading The System Software And Installing Subboards On The Cbcpr - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

4.3.5
Loading the System Software and Installing Subboards on the
CBCPR
Caution
7
Always wear an antistatic wristband when working on the system (especially when
handling boards). Connect the wristband to the slide-in shelf in the cabinet using the
alligator clip.
The cabinets are already equipped with the boards needed for the customer-specific require-
ments when the system is delivered.
The central control boards are not always fully equipped when delivered. Optional plug-in
boards are packaged individually.
See Chapter 3 for information on slots for subboards on the central control boards.
Caution
7
Place the central control board on a flat surface before installing subboards.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
inst_h3.fm
4-151