Siemens HiPath 3000 Service Manual page 565

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

Grounding the system cabinets and patch panels
HiPath 3700, EC2 (if present)
HiPath 3700, EC1 (if present)
HiPath 3700, BC
green/yellow
Min. cross-section = 2.5 mm
Figure 4-75
HiPath 3700- Grounding the Systems and Patch Panels in a 19-Inch Cabinet
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Attach to the grill
using cable ties
Any color, except for green or
yellow to avoid confusion
Min. cross-section = 2.5 mm
2
Potential equalization bus,
in 19" cabinet for example
Installing HiPath 3750, HiPath 3700
To other patch panels S30807-
K6143-X (if present)
(A ground conductor is not re-
quired for the S
S30807-K6143-X.)
Patch Panel
S30807-K6143-X
inst_h3.fm
Installing HiPath 3000
patch panel
0
2
4-135