___________________________________________________________________________________
4-52
CO/PBX Answer Key Operation
Without Ringing Assignment (Day
Mode)
General Description
Use this Memory Block to specify whether or not day assignment Answer key
operation uses ringing. When NO is selected, press the Answer key while an incoming
CO line key is flashing to answer the line key call. When YS is selected, the telephone
must be ringing for the Answer Key to answer an incoming CO/PBX call.
Display
T e l
P o r t
D a t a
N o .
~
N o .
( 0 1
C 0 )
0 1 / 5 2 : R I N G
T I M E
Settings
LK 1
LK 2
NO
YS
Programming Procedures
1 Go off-line.
E B
2 Press LK4 +
3 Press LK1 to disable ringing for answer key operation for Tel Port No.
Use the following to enter data:
J
t o move the cursor left
L
t o move the cursor right
K
I
~
t o enter numeric data or Tel Port No.
D
– OR –
B
to go to next assigned Tel Port No.
B
A
+
B
B
+
C
G
+
4 Press
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
___________________________________________________________________________________
2 - 566
S e t t i n g
T i t l e
D a t a
D
Y S
D I S P L A Y
LK 3
LK 4
LK 5
to access the Memory Block.
t o enter A for Port Numbers 100~109
t o enter B for Port Numbers 110~119
t o enter C for Port Number 120
E
LK 6
LK 7
to go back on-line.
Electra Elite IPK
Telephone Mode
4
Submode
Data No.
52
PC Programming
+BTT
LK 8
The shaded
selection is the
default.