1-16-12 Mirroring Target Port Assignment - NEC Electra Elite IPK Programming Manual

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Electra Elite IPK
___________________________________________________________________________________

1-16-12 Mirroring Target Port Assignment

General Description
When Port Mirroring is enabled in Memory Block 1-16-10 (Port Mirroring Selection),
use this Memory Block to specify a target port that monitors frames transmitted on the
source port specified by Memory Block 1-16-11 (Mirroring Source Port Assigment) for
each HUB(8)-U( ) ETU. The source port and target port must be in the same VLAN(s).
R1500 or higher is required.
Display
D a t a
H U B
N o .
1 ~ 3
1 2 : 1
T I M E
Programming Procedures
1 Go off-line.
J J A B
2 Press LK1 + LK16 +
3 Use dial pad keys to enter Setting data.
Use the following to enter data:
J
Use
t o move cursor left
L
Use
t o move cursor right
K
I
Use
~
Port range is 1~8.
G
4 Press
to write the data.
5 Repeat steps 3 and 4 for each HUB(8)-U( ) ETU.
E
6 Press
to go back on-line.
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
T A R G E T
= 1
D I S P L A Y
to access the Memory Block.
t o enter numeric data
Document Revision 4
System Mode
Submode
Data No.
PC Programming
Default Values :
Port 1
1
16
12
+AB