___________________________________________________________________________________
1-1-60

8-Digit Matching Table Assignment

General Description
Use this Memory Block to assign the outgoing dial digit for Code Restriction (except
OCC Dial Digit - Normal Dial). Program this assignment in one of two ways:
a) When the user dials digit(s) and there is a match, the system allows free dialing or
denies dialing by disconnecting. Refer to Memory Block 1-1-61 (8-Digit Matching
Table to Class Assignment) for programming.
b) When a user dials digit(s) and there is no match, the system allows free dialing or
denies dialing by disconnecting. Refer to Memory Block 1-1-65 (Code Restriction
Class Allow/Deny Selection) for programming.
Display
D a t a
N o .
6 0 : 8 D I G I T
0 0 / 0 0 = 9 1 1
8 - D i g i t
D i a l
M a t c h i n g
C o d e
T a b l e
Programming Procedures
1 Go off-line.
F K
2 Press LK1 + LK1 +
3 Use the dial pad to enter the data for Dial Code 00 for 8-Digit Matching Table 00.
Use the following to enter data:
J
t o move the cursor left
L
t o move the cursor right
K
I
H
~
t o enter numeric data
to clear data
The information that can be entered includes:
Matching Table: 00~15 (8-digit)
Dial Code:
Dial Digit:
___________________________________________________________________________________
2 - 78
T i t l e
T A B L E
D i a l D i g i t
( m a x . 8 )
to access the Memory Block.
00~15
0~9, , #, NANP = X, P, N (Maximum eight digits)
Electra Elite IPK
System Mode
Submode
Data No.
PC Programming
Default Values
Matching
Dial
Table
Code
00
00
911
11
00
0
12
00
976
13
00/ 01/02 1800/1888/1877
14
00
1X
15
00
X
Memory Blocks
1
1
60
+AC
Setting
Data