1-1-50
CO/PBX Outgoing Digit Add
Assignment
General Description
Use this Memory Block to specify up to 10 additional digits when a trunk in the Trunk
group or Route Advance block assigned in Memory Block 1-1-49 (Networking Trunk
Group/Route Advance Assignment) is seized, and a number is dialed.
Display
C l o s e d
N u m b e r
D a t a
B l o c k
N o .
0 1 ~ 1 6
5 0 : 0 1 =
T I M E
Programming Procedures
1 Go off-line.
E K
2 Press LK1 + LK1 +
3 Use dial pad to enter digits to be added for Closed Number Block 01.
Use the following to enter data:
J
t o move the cursor left
L
t o move the cursor right
K
I
H
t o enter numeric data
~
B
to clear all data
J
B
+
L
+
G
4 Press
to write selected data and display the next Closed Number Block.
5 Repeat Steps 3 and 4 for each Closed Number Block. After data for the last Closed Number Block is written, the next Memory
Block is displayed.
6 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
1-1-46
Access Code (1-Digit) Assignment
1-1-49
Networking Trunk Group/Route Advance Assignment
___________________________________________________________________________________
Programming Manual
A d d
D i g i t
1 0 M a x .
D I S P L A Y
to access the Memory Block.
t o enter
t o enter #
E
to go back on-line.
Document Revision 4
System Mode
1
Submode
1
Data No.
50
PC Programming
+BCS
Default Values
Not Specified
2 - 65