NEC Electra Elite IPK Programming Manual page 707

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Document Revision 4
___________________________________________________________________________________
G
E
5 Press
to write the data.
6 Press
to go back on-line.
KSU Power-Based ETU Quantity Limitations
The following charts indicate the maximum number of specific ETU combinations in each KSU that are restricted by
power limitations of the KSU.
For System without EliteMail VP/CTI or CTI ETU loaded with Q-Master application
NO. of
NO. of ESI(8)
ETUs
ESI Ports
10
80
9
72
8
64
7
56
6
48
5
40
4
32
3
24
2
16
1
8
The number of 8-port ESI ETUs installed including ESI(8)-U( ), ESIB(8)-U( ), or ESIE(8)-U( ) ETU.
When the SPE(M)-U( ) ETU or the MIFM-U20 ETU (with Ethernet option installed) is installed in
the AP slot, the HUB(8)-U( ) ETU or Elite Mail CIT/VP must be installed in a different cabinet.
Only one CTI ETU can be installed in a KSU (EliteMail, VP, or Q-Master).
___________________________________________________________________________________
2 - 630
ACD+/CMS/FMS/VMP/
Either
VMS/IPC/MG/IVR/IPT/
EliteMail VP/CTI
IAD/SLI/OPX/BSU(4M)/
BSU(2S)/BSU(6S) or
0
0
0
0
0
0
0
0
0
0
Maximum NO. of
DID ETUs
2
2
3
4
5
5
6
6
7
7
Electra Elite IPK
Other ETUs
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
No Limitation
Memory Blocks