Call Forward - No Answer Time Selection - NEC Electra Elite IPK Programming Manual

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Document Revision 4
___________________________________________________________________________________
1-2-22
Call Forward - No Answer Time
Selection
General Description
Use this Memory Block to specify the time before incoming intercom calls or incoming
CO/PBX lines are forwarded to another station number when the called party does not
answer.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
D a t a
N o .
2 2 : F W D
T I M E
Settings
LK 1
LK 2
4s
8s
Programming Procedures
1 Go off-line.
B B
2 Press LK1 + LK2 +
3 Press the corresponding CO/PBX line key to change the data option.
G
4 Press
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
Refer to next page for R3000 or higher Programming Procedures.
___________________________________________________________________________________
2 - 122
S e t t i n g
T i t l e
D a t a
N O A N S
D I S P L A Y
LK 3
LK 4
LK 5
12s
18s
24s
to access the Memory Block.
E
to go back on-line.
8 s
LK 6
LK 7
30s
60s
Electra Elite IPK
System Mode
1
Submode
2
Data No.
22
PC Programming
+BM
LK 8
The shaded
selection is the
default.
Memory Blocks

Hide quick links:

Advertisement

Table of Contents
loading