Display (R3000 or higher)
D a t a
N o .
0 1 : A A
T I M E
Programming Procedures
1 Go off-line.
J
2 Press LK1 + LK4 +
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
G
01s~99s (e.g., 02s = 2s)
4 Press
to write the data and display the next memory block.
5 Program the next memory block, or press
Related Programming
M.B. Number
Memory Block Name
4-71
Station to Timer Class of Service (R3000 or higher)
1.
After PBR is connected, dialing must be completed in the specified time. After the first digit is dialed, interdigit
time (default 7 sec.) controls the PBR time. Dialing the third digit exceeds the 20 sec. default, and the PBR is
disconnected.
2.
R3000 or higher is required to adjust this memory block by 1-second intervals.
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
P B R R L S
2 0 s
D I S P L A Y
A
+
to access the Memory Block.
E
Notes
to go back on-line.