NEC Electra Elite IPK Programming Manual page 49

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Document Revision 4
___________________________________________________________________________________
LK 1 System Mode
LK 1 CO Line (Continued)
Data
Memory Block Name
No.
63
Hold Recall Time Selection
(Exclusive)
65
Code Restriction Class Allow/Deny
Selection
66
8-Digit Matching Table to Normal
Dial Assignment
67
OCC Table Assignment
68
8-Digit Matching Table to OCC
Table Assignment
69
Tie Line Code Restriction
Assignment
70
Code Restriction Class Assignment
when Lockout is Set
71
First Delay Announcement Start
Time Selection
72
First Delay Announcement Repeat
Selection
73
First to Second Delay
Announcement Interval Time
Selection
74
Second Delay Announcement
Repeat Selection
75
Second Delay Announcement
Repeat Interval Time Selection
76
Barge-In Alert Tone Assignment
___________________________________________________________________________________
1 - 16
Default Value
1.0 (R2500 or lower)
060s (R3000 or
higher)
Class 01 ~ 04 – YS
Class 05 ~ 14 – NO
Tables 00 ~ 14 =
Used
(All CO/PBX Line
LEDs On)
Table 15 = Unused
(CO/PBX Line LED
Off)
Tables 00 ~ 15 =
Blank
Table 16 =
1010XXX
CO/PBX Line LED
Off
YS
15
20
1
20
1
20
YS
Electra Elite IPK
Programming Values
In minutes: 0.5, 1.0, 1.5, 2.0, 3.0,
5.0, 8.0, ∞ (No Limit) (R2500 or lower)
000s (No Limit), 001s~999s (R3000 or
higher)
YS (Allow)
NO (Deny)
N/A
N/A
Refer to
1-1-68 8-Digit Matching Table
to OCC Table Assignment on page
2-88.
NO = No Restriction
YS = Restriction
Class 00 ~ 15
In seconds: 00, 10, 20, 30, 40, 50, 60
1, 2, 3, 4, 5, 6, 7, 8
In seconds: 00, 10, 20, 30, 40, 50, 60,
∞ (No Limit)
1~ 8
In seconds: 00, 10, 20, 30, 40, 50, 60,
∞ (No Limit)
YS = Send Alert Tone
NO = Do not send Alert Tone
Multiline Terminal Programming