___________________________________________________________________________________
Display (R3000 or higher)
D a t a
N o .
0 6 : R I N G
T I M E
Display
Programming Procedures
1 Go off-line.
K F
2 Press LK1 + LK1 +
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
G
000s~255s (e.g., 020s = 20s)
4 Press
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
1-1-07
Tie Line Delay Ringing Time Selection
3-07
CO/PBX Ringing Variation Selection
4-01
CO/PBX Ring Assignment (Day Mode)
4-02
CO/PBX Ring Assignment (Night Mode)
4-91
Telephone Ringing Variation Selection
1.
Memory Blocks 4-01 and 4-02 [CO/PBX Ring Assignment (Day Mode/Night Mode)] must be set to ring.
2.
CO/PBX lines assigned for DIT/ANA do not activate this feature.
3.
Tie/DID lines assigned for Delayed Ringing follow this assignment after the delayed ringing starts.
4.
This feature uses the same ringing tone (Low, Medium, High) that is selected in Memory Blocks 3-07 (CO/PBX
Ringing Variation Selection) and 4-91 (Telephone Ringing Variation Selection). When High is selected in these
Memory Blocks, this feature does not function.
5.
Select
(No Limit) to disable this feature.
6.
When a system is upgraded from R2500 or lower, the Start Time Selection is reset to the default value during
the upgrade process (R3000 or higher)
___________________________________________________________________________________
2 - 12
S e t t i n g
D a t a
T i t l e
A L M
0 0 0 s
D I S P L A Y
t o access the Memory Block.
E
to go back on-line.
.
Notes
Electra Elite IPK
Default Values
000s