Avaya DEFINITY Server CSI Maintenance Manual page 1599

Table of Contents

Advertisement

SYNC (Synchronization)
Table 460. Synchronization Error Log Entries — Continued
Aux
Error Type
Data
4
1793
0-50
4
2049 (f) (h)
0
4
2305 (g) (h)
0
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the value of set options, then, after a period of time, a Minor or
Major alarm is raised.
3.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
4.
It may take up to one hour for these SYNC alarms to clear due to "leaky bucket" strategy.
Notes:
a. This error indicates a problem with the primary DS1 reference. It is cleared
when the primary reference is restored. The following steps should give an
indication of the source of the problem:
1. Check if the primary DS1 interface circuit pack is inserted in the
2. Check the connection of the cable supplying the external timing
3. Test the primary DS1 interface circuit pack via the test board PCSS
4. Test the active Tone-Clock circuit pack in the master port network
555-233-119
Associated Test
None
MAJOR/
WARNING
None
WARNING
None
WARNING
carrier via the list configuration board PCSS command.
source to the primary DS1 interface circuit pack.
long command. Check the Error Log for DS1-BD errors and refer to
the DS1-BD (DS1 Interface Circuit Pack) Maintenance
documentation to resolve any errors associated with the primary
DS1 interface circuit pack. If no errors are listed in the Error Log for
the primary DS1 interface circuit pack, continue with the following
steps.
via the test tone/clock PC long command. Check the Error Log for
TDM-CLK errors and verify that TDM Bus Clock Test #148 passes
successfully. If Test #148 fails with an Error Code 2 through 32, refer
to
''TDM-CLK (TDM Bus Clock)''
continue with the following steps.
Alarm
On/Off
Level
Board
OFF
OFF
OFF
Continued on next page
to resolve the problem. If not,
Issue 5 October 2002
Test to Clear Value
enable sync
None
None
1599

Hide quick links:

Advertisement

Table of Contents
loading