Rem-Off (Remote Office) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Objects

REM-OFF (Remote Office)

MO Name (in
Alarm Log)
Alarm Level
REM-OFF
MIN
REM-OFF
WRN
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation (A, B,
C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
An instance of this maintenance object (REM-OFF) is associated with every
Remote Office box that is administered on the switch. This maintenance object
monitors keep alive and periodic PING test failures, and if these errors occur, they
are logged against this maintenance object.
Error Log Entries and Test to Clear Values
Table 443. Analog Line Error Log Entries
Error
Aux
Type
Data
1(a)
257(b)
See
note (b)
Notes:
a. Error Type - 1 — indicates that a PING Test to the Remote Office has
failed, and a MINOR alarm has been raised.
The PING test verifies that a path to a registered Remote Office is good.
When this error is logged, as many as 26 endpoints (associated with that
Remote Office) and several H.323 signaling groups could be out of service.
1568
Issue 5 October 2002
Initial Command to Run
ping
node-name/ip-address
ping
node-name/ip-address
Associated
Alarm
Test
Level
A ping test
MINOR
to an
endpoint has
failed
A keep alive
Log only
update
request has
exceeded
the time limit
for an
endpoint
1
Full Name of MO
Remote Office
Remote Office
On/Off
Board
Test to Clear Value
OFF
ping
node-name/ip-address
OFF
ping
node-name/ip-address

Hide quick links: