Nortel DMS-100 Series Replacement Procedures page 530

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-498 XPM card replacement procedures (continued)
NTBX02
in an RSC-S (PCM-30) Model B RCO2
4
5
6
297-8021-547 Standard 14.02 May 2001
Ensure the PM level of the MAP display is currently displayed and the RCO2
with the faulty DCH card is posted by typing
>MAPCI;MTC;PM;POST RCO2 rco2_no
and pressing the Enter key.
where
rco2_no
is the number of the RCO2 with the faulty card
Example of a MAP display:
CM
MS
IOD
Net
.
.
.
RCO2
SysB
0 Quit
PM
2 Post_
RCO2
3 ListSet
4
RCO2
0
5 TRNSL
Unit0:
Inact InSv
6 TST
Unit1:
Act InSv
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13
14 QueryPM
15 DCH
16
17
18
Refer to the MAP display posted in step 4 to see if the faulty NTBX02 card is
in the active or inactive unit.
If faulty card is in
active unit
inactive unit
Switch the processing activity (SWACT) to the inactive unit by typing
>SWACT
and pressing the Enter key.
If SWACT
cannot continue at this time
(continued)
PM
CCS
LNS
.
.
.
.
ManB
OffL
0
0
0
0
0
0
Links_OOS:
CSide
Do
step 6
step 10
Do
step 7
Trks
Ext
Appl
.
.
.
CBsy
ISTb
0
0
0
0
0, PSide
0
InSv
25
0

Advertisement

Table of Contents
loading

Table of Contents